<PS>E HCV 182

Product Category:Solar Cable

Product Description:PSE HCV 182 Acc. to JIS C 3605 certification. JCT TAINETU 600V HCV 1X**mm CARDIFF 20** LF Construction: Conductor: Fine strands of bare copper, acc. to JIS C 3102 Insulation: XLPE Insulation colour: White Outer sheath: Special PVC compound

Detailed
<PS>E HCV 182


Acc. to JIS C 3605 certification.
 

   JCT TAINETU 600V HCV 1X**mm² CARDIFF 20** LF
 
Construction:
Conductor: Fine strands of bare copper, acc. to JIS C 3102
Insulation: XLPE
Insulation colour: White
Outer sheath: Special PVC compound
Sheath colour: Black, RAL 9005
 
Technical data:
Rated voltage : 600V AC
Test voltage  : 1500V
Ambient Temp.: -15℃ to +90℃
Bending radius : D<8mm: 4x cable diameter
D≥8mm: 6x cable diameter
Weathering & UV-resistance: JIS K 7350-1 & JIS K 7350-2
Cold bending test: JIS C 3005
Burning behavior : JIS C 3005
Smoke density  : JIS C 0081
 

Part No. Cores No. + area (mm²) Conductor structure (core/mm)  Conductor Diameter (mm) Approx. Diameter (mm) Max conductor DC resistance (20℃; Ω/KM) Approx. Weight (kg/km)
182 0020 001 11 2.0 7/0.6 1.80 6.4 9.24 55.0
182 0035 001 11 3.5 7/0.8 2.40 7.0 5.20 75.0
182 0055 001 11 5.5 7/1.0 3.00 8.0 3.33 105.0
182 0080 001 11 8.0 7/1.2 3.60 8.6 2.31 140.0